IES
How can I prepare for Ies from 2nd year onwards?
-
-
Hysteresis Loss
What is the effect of hysteresis loss in transformer/machines especially in DC one?
-
Two Phase Induction Motors
Why 2-phase induction motors are NOT used in industries even though they have rotating magnetic field.
-
Induction Motor Phase Swinging or Hunting
What is Phase Swinging or Hunting in Induction Motor?
-
Electrical Machines
Why we are preferring 4 pole alternator in the production of electric power instead of 2 pole alternator ?
-
IDMT and Buchholz Relay
A) IDMT relay are mostly used for protection against?
1) Earth Fault 2) Inter turn fault 3) Overloading 4) None of the above
B) Which device is provided as backup of buchholz relay?
C) Name any two devices used for protection of power transformer against internal faults?
-
Induction Motor Rotation Direction
Why does Table Fan rotates Clockwise while Ceiling Fan rotates anti-clockwise? Any technical reason?
-
Why neutral is not used in Delta Circuit?
We are using neutral in Star Circuit and same in Delta Circuit is not used. What is the reason? Explain in brief.
-
Q-point in transistor?
What is the purpose of Q-point in transistor?
-
Earthing & Grounding
What is the difference between Earthing & grounding?
-
Power Electronics - Determine Resistor, Capacitor and Inductor Using a Battery, a switch and a Lamp.
you have three boxes, one has a resistor, second has a capacitor, and the third has an inductor. Find what is in each box, using a battery, a switch and a lamp. You can build any circuit you want, to figure out which box have a resistor, and which one has the inductor, etc. How can you solve that?
-
Slip Power Recovery System
How does Slip Power Recovery System work? How to capture supply for recovery? Is it any possibility to design model of slip power recovery system drive?
-
Distributed and Concentrated Winding
What is meant by distributed winding and concentrated winding?
-
Star or Delta Transformer Selection
How can we chose transformer star to delta or delta to star connection? What condition is suitable for star connection? What condition is suitable for delta transformer?
-
Measure Reactive Power
How can we make wattmeter to measure reactive power?
-
-
Over Exited Alternator
When alternator is over exited, the power factor will be
a. Lagging
b. Leading
c. Zero -
Poor performance for user programs
What percentage of system overhead will not result in poor performance for user programs?
>10%
>20%
-
Harmonics Power System
What are the advantages & dis-advantages of Harmonics in Power System?
Electrical Engineering Interview Questions
Ans